Symptoms:
Multiple error code 50's
Possibly Intermittent
Error codes continue to exists after removing pulser from the meter
Environment:
Give details about the environment that this symptom is relevant to.
- Single pump
- Effects one or both sides
Cause:
The error can be caused by jitter or excessive reverse flow but it can also be caused when the system does not see the pulser via the jumper on its cable
Resolution:
- Follow cable line up thru the ISB (Intrinsically Safe Barrier).
- Check for loose pins or connections
- Reseat connections near or feeding thru the ISB